T-1 Cables
The cable products outlined here are designed for a multitude of telecommunications uses, including:
- T-1, T-3
- HI-CAP
- Central Office Interconnects
- Primary rate ISDN, DSL, HDSL, ADSL, SDSL, VDSL
The product line is offered in Plenum, Riser and General Rated Safety Compliance so it is suitable for any installation environment. All of these cables are in stock from 2 Twisted Pairs to 56 Twisted Pairs.
Key Features
- Termination Compatibility – Wire wrap, Punch down Block and RJ 45 connectorization compatibility.
- Cat 5 type electrical characteristics that provide the widest signal bandwidth and future application upgrade potential.
- Excellent impedance stability across transmission frequency spectrum.
- Complete send and receive signal isolation.
- Full safety compliance.
- The shields of the send and receive groups are color coded, making for faster, easier, more accurate termination and eliminating the need to continuity test.
- Cables are sequentially marked for footage. This coupled with the send and receive groups under one jacket eliminates the need for cutting and paralleling prior to installation. This feature also eliminates mismatched lengths and other waste generating mistakes. Ripcords under jackets provide termination ease and accuracy.
Performance Compliance
Bellcore TA-TSY-000131 Customer Premises Plenum Cables and Wire Bellcore TA-TSY-000132 Customer Premise Shielded Station Wire Bellcore TA-TSY-0000140 Standard Shielded Twisted Pair Cables
Safety Compliance
Underwriters Lab- Subject 13, 444, 910 and 1581 Canadian Standards Association – PCC FT 6 National Electric Code- Article 800 CPM(Plenum) CMR(Riser) CM(General)
Physical and Environmental | |
---|---|
Conductor AWG | #24 Tinned Copper |
Pair Counts Available in stock | 2,6,10,16,28 and 56 Pairs* Custom items can be made to your specific needs for number of pairs |
Melting Point | 275 Degrees C |
Flashpoint | 655 Degrees C |
Degradation Temperature | 425 Degrees C |
Embrittlement Temperature | -196 Degrees C |
Fuel Value | >2200, < 6600 |
C NET Corrositivity | < 15 |
Abrasion Resistance Coefficient | <833 Scrapes/Mil |
Electrical | |
---|---|
Characteristic Impedance | 100 +/-4 Ohms @ 772 kHz |
Attenuation | 6.7 db/1000 Ft @ 772 kHz |
Near End Crosstalk | 85 db @ 1.544 MHz90 db @ 772 kHz |
Insertion Loss | <10 db/1000 @ 1.544 MHz< 7 db @ 772 kHz |
Capacitance | 15 Picofareds/Foot Max |
DC Resistance | < 28.6 Ohms/1000 Ft |
T-1 Distance | 480 Ft |
T-1 Parts | |
---|---|
21531 | 2 PR #24 T-1 Plenum Special Cap |
21545 | 6 PR #24 T-1 Plenum Special Cap |
21518A | 10 PR #24 T-1 Plenum Special Cap |
21519A | 16 PR #24 T-1 Plenum Special Cap |
21522A | 28 PR #24 T-1 Plenum Special Cap |
21523 | 56 PR #24 T-1 Plenum Special Cap |
21551 | 2 PR #24 T-1 PVC Special Cap |
21612 | 6 PR #24 T-1 PVC Special Cap |
21613 | 10 PR #24 T-1 PVC Special Cap |
21614 | 16 PR #24 T-1 PVC Special Cap |
21615 | 28 PR #24 T-1 PVC Special Cap |
21743 | 56 PR #24 T-1 PVC Special Cap |
Address
425 Shrewsbury Street
Worcester, MA 01604
Phone
(508) 752-8260
info@generalwireproducts.com