508.752.8260

93 Ohm Data Coaxial – Plenum + Non-Plenum

 

93 OHM Coaxial

Coaxial Cable Construction Abbreviation Key

Conductor

Solid or stranded; conductor diameter is included.

  • BC – Bare Copper
  • TC – Tinned Copper
  • SPC- Silver Plated Copper
  • CCS – Copper Covered Steel

Dielectric

Foamed or solid, and engineered for desired impedance. Dielectric diameter included for connector compatibility.

  • PE – Polyethylene
  • FEP – Fluorinated Ethylene Propylene
  • FPE – Foamed Polyethylene
  • FF – Fluorofoam
  • AS-PE – Air Spaced Polyethylene
  • AS-FEP – Air Spaced Fluorinated Ethylene Propylene

Shielding

Foil and copper shields are utilized. Dependant shield effectiveness and signal loss requirements. Copper shields can be braided or served. Foil shields provide 100% coverage. Braided or served shields coverage percentage is designated in each individual coaxial specification.

  • AM Foil – Aluminum Mylar Polyester Tape
  • BCSS – Bare Copper Served Shield
  • BCBS – Bare Copper Braid Shield
  • TCSS – Tinned Copper Served Shield
  • TCBS – Tinned Copper Braid Shield
  • SPCSS – Silver Plated Copper Served Shield
  • SPCBS – Silver Plated Copper Braid Shield

Jackets

Jacket material selection is dependent on the cable application and safety rating.

  • FR-PVC – Flame Retardant PVC – Riser and General Purpose rated
  • TPE – Thermo Plastic Elastomer – Highly Flexible
  • PU – Polyurethane – High Flexibility, Chemical and Abrasion Qualities
  • PE – Polyethylene for Outdoor and Direct Burial Applications
  • FEP – Fluorinated Ethylene Propylene- Plenum Rated 200 Degrees C
  • HALAR – ECTFE – Plenum Rated 150 Degrees C
  • KYNAR – PVDF – Plenum Rated 125-150 Degrees C
  • PlenAlloy – Plenum Rated PVC – 75 Degrees C
Part No.RG & UL TypeConductor ODDielectric ODShield Type CoverageJacket ThicknessOD InchesCapacitance ImpedanceVP %
62RG 62 A/U CM/CL2#22 Solid CCS 0.025PAS-PE 0.146BCBS 95%FR-PVC 0.0340.24213.5 93 Ohms85%
30062RG 62 A/U CMP/CL2P#22 Solid CCS 0.025AS-FEP 0.146BCBS 95%Plen Alloy 0.0150.20413.5 93 Ohms85%
63RG 62 U CM/CL2#22 Solid BC 0.025FPE 0.146BCBS 95%FR-PVC 0.0340.24213.5 93 Ohms84%
21462RG 62 U CMP/CL2P#22 Solid BC 0.025FF 0.146BCBS 95%Plen Alloy 0.0150.20413.5 93 Ohms84%
Part No.DescriptionUL TypeCapImpedanceOD
736011TP # 24 7/32 TC Ind Shield Plenum CMP/CL3P12.5100 Ohms0.150
736022TP # 24 7/32 TC Ind Shield Plenum CMP/CL3P12.5100 Ohms0.230
736033TP # 24 7/32 TC Ind Shield Plenum CMP/CL3P12.5100 Ohms0.250
739011 TP # 18 7/26 TC Ind Shield Plenum CMP/CL3P2260 Ohms.0175
213071TP # 24 7/32 TC Ind Shield Foil & BraidCMP/CL3P10.8120 Ohms0.195
896922TP # 24 7/32 TC Ind Shield Foil & Braid Plenum RS 485CMP/CL3P10.8120 Ohms0.240
218901TP # 22 SBC LON Works UTPCMP/CL3P12100 Ohms0.115
218511TP # 22 7/30 BC LON Works UTPCMP/CL3P12100 Ohms0.125
218921 TP # 22 7/30 BC LON Works STPCMP/CL3P12100 Ohms0.180
217561 TP #22 7/30 BC Ind Shielded Plenum ARC 156CMP/CL3P12.5100 Ohms0.157
515022 TP #22 7/30 BC LONWORKS UTPCMP/CL3P12100 Ohms0.191
234411.5 TP 24 AWGCMP/CL3P12.5 PF/FT100 Ohms0.186
234991.5 TP 24 AWG RS485CMP/CL3P11 PF/FT120 Ohms0.207
General Wire Industry Certifications
General Wire Products is ISO 9001:2015 Certified
General Wire is a DOD-approved supplier
General Wire Products is UL200 Certified
General Wire Products is ETL Certified
General Wire Products is NEC Certified
CSA Certification

Address

425 Shrewsbury Street
Worcester, MA 01604

Phone

(508) 752-8260

Email