Conductor - Solid or Stranded - Conductor
diameter is included
Dielectric - Foamed or Solid - Engineered for
desired impedance. Dielectric diameter included for connector
compatibility
-
PE -
Polyethylene
-
FEP -
Fluorinated Ethylene Propylene
-
FPE - Foamed
Polyethylene
-
FF - Fluorofoam
-
AS-PE - Air
Spaced Polyethylene
-
AS-FEP - Air
Spaced Fluorinated Ethylene Propylene
Shielding - Foil and copper shields are utilized.
dependant shield effectiveness and signal loss requirements. Copper
shields can be braided or served. Foil shields provide 100% coverage.
Braided or served shields coverage percentage is designated in each
individual coaxial specification.
-
AM Foil -
Aluminum Mylar Polyester Tape
-
BCSS - Bare
Copper Served Shield
-
BCBS - Bare
Copper Braid Shield
-
TCSS - Tinned
Copper Served Shield
-
TCBS - Tinned
Copper Braid Shield
-
SPCSS - Silver
Plated Copper Served Shield
-
SPCBS - Silver
Plated Copper Braid Shield
Jackets - Jacket material
selection is dependent on the cable application and safety rating.
-
FR-PVC - Flame
Retardant PVC - Riser and General Purpose rated
-
TPE - Thermo
Plastic Elastomer - Highly Flexible
-
PU -
Polyurethane - High Flexibility, Chemical and Abrasion Qualities
-
PE -
Polyethylene for Outdoor and Direct Burial Applications
-
FEP -
Fluorinated Ethylene Propylene- Plenum Rated 200 Degrees C
-
HALAR - ECTFE -
Plenum Rated 150 Degrees C
-
KYNAR - PVDF -
Plenum Rated 125-150 Degrees C
-
PlenAlloy -
Plenum Rated PVC - 75 Degrees C
|